Model
2300 & 2350
Flow
Indicator/Totalizers |
Flow
Meters & Instrumentation |
|
|

|
Flow Indication with Totalizer
- Standard indication of flowrate and totalized flow
Large Digital Display -3.5-mm
character height
Easy Calibration -
Calibration is done through the keypad, no tools or equipment are required
NEMA 4X Enclosure - Corrosion
resistant
Versatile Mounting -
Panel-mounting or optional wall-mounting enclosure
Flow Alarms -
Model 2350 has user-selectable High and Low flow alarms as standard
Model 2350 (only)
Alarms: Two adjustable
High and Low alarms, indicated on display
Relays: Two unpowered
SPDT contacts rated 66 VA. Relays are activated on rising flowrate (set
at Low Alarm 2 and High Alarm 2) and are deactivated on falling flowrate
(set at Low Alarm 1 and High Alarm 1) |
|
. |
 |
|
| FloSite Models 2300 and 2350 are panel-mounted instruments
that provide large, easy-to-read digital indication (numeric characters
are 13.5 mm high) of both flow rate and totalized flow. The Model 2350
also has Low and High flow alarms and relay contacts actuated at user-selectable
levels, typically used for remote indication or control.
Used with Model 2000 flow sensors, these NEMA 4X compact
monitors are simple to operate and calibrate. A front keypad with three
pushbuttons provides the user interface to toggle the display between flow
rate and totalized flow, reset the total, and calibrate the display. Calibration
is easy and merely involves entering a scaling factor based on type and
size of installation fitting used. |
|
. |
Wall Mounting Enclosure |
|
| Models 2300 & 2350
Display Type: 6-digit LCD for flow rate or totalized
flow (user-selectable)
Volumetric Units: Flow rate in GPM, totalized
flow in gallons
Operating Range: 6.3 to 420 Hz
Input: Square wave, 12 to 24 V p-p from Model
2000 sensor
Sensor to Indicator Distance: Up to 325 ft (100
m)
Accuracy: ±1 % of indicated flow over the
full calibrated range
Power Requirement: 110 V AC, 50/60 Hz or 24 V
DC. Note: indicator provides 12 V DC power to the sensor
Electrical Connection: 8-point (Model 2300) or
15-point (Model 2350) terminal strip on rear of unit
Enclosure Rating: NEMA 4X (IP65) when panel mounted
Operating Temperature: 32 to 140F (0 to 60C)
Enclosure Materials: ABS
Mounting: Panel
Options: Wall-mounting enclosure (rated NEMA 4X)
with two cable glands to accept 4-conductor shielded cable from sensor
Dimensions
Halar is
a TM of Ausimont USA Inc.
Viton is a TM of DuPont Dow Elastomers |
|
|
|